XL-535 automatic burning test machine
Test standards:UL-62、758、1581
Application:The machine is testing the insulator or the covered fire. The test method is to hold the test material at the top of the flame, which is not exposed to the blow. It burns 15 seconds, extinguishes 15 seconds, and repeated 5 times, and examines the burn rate of the test. Type XL - 535, can set fire, interval number and test times and automatic operation. The machine consists of three parts: vertical box, horizontal box and control box.
Technical parameters:
1.specimen length: 300、457mm 2.fuel:methane, gas (self-prepared) 3.timer: 2 groups,0~99 seconds
4.counter: 0~9999×100 times 5.vertical volume: 32×37×67cm 6.horizontal volume: 62×32×35cm
7.Control chamber volume:34×24×33cm 8.weight: 12kg+10kg+ 28kg 9.power: 1∮,AC220V,1A